Industrial and Medical Gas Installations
Hover to Zoom

Last Updated
10 Feb 2021
Country Origin
Indonesia
Minimum Order
1 unit

Specification of Industrial and Medical Gas Installations

Industrial and Medical Gas Installations

Central systems and industrial gas central medical gas.
Gas distributing medical / industrial gas from gas central chamber to the patient or user space by passing through a copper pipe in the pipe material commonly used are copper pipes or stainless stenlis equipped with alarm system, Zone Vavle, outlets and flowmeter or regulator.
1 SCOPE OF MEDICAL GAS SYSTEM

a. Central space.
b. Piping systems and installation.
c. Secondary Equipment.

2 TYPES OF GAS MEDICAL
Types of medical gas which is used for hospital use is as follows:
Oxygen (O2)
Nitrous Oxide (N, O)
Medical Compressed Air (Air Breathing)
Vacuum (Suction)
Oxygen is available in the form of gas and liquid (Liquid) are packed in a steel tube (Cylinder) 6m³ volume. Liquid Oxygen (liquid) packaged in a steel tube (cryogenic liquid storage unit).
Rooms that use medical oxygen in hospital:
Emergency Unit (Emergency)
ICU and ICCU
Surgical Unit / Central
section Anesthesia
Part Awareness / Healing (RR)
part Maternity
nursery
Inpatient space
In central oxygen, used automatic changeover device which lowers the gas pressure of the tube to the gas pressure constant 4, 0 kg / cm and provide all distribution channels.

2.2 Nitrous Oxide (N20)
Rooms that use nitrous oxide to the hospital:
ICU and ICCU
Operating Rooms
Rooms work
Rooms endoscopy
Dental operating room

2.3 MEDICAL Compressed Air (BREATHING AIR)
Medical Compressed Air used in hospitals procured through a central installation of compressed air. Compressed air produced must coexist, dry, oil-free and free of bacteria.
Compressed Air System consists of:
1. Oil Free Compressor: L unit working with air pressure up to 7 kg / cm².
Motor: 2.2 KW induction motors, 3 Phase, 200/220 Volt, 50 / 60Hz. Maximum pressure: 10 kg / cm². Rev the engine: 1450 rpm.
2. Water cooled after cooler.
The maximum pressure during the operation: 10 kg / cm².
3. Receiver Tank.
4. Medical Air Unit

2.4 VACUM (SUCTION)
Vacuum installed in the hospital working at a pressure of -53 kPa to -80 kPa dengaan.
Rooms that use Vacuum at the hospital:
ICU and ICCU
Operating Rooms
Endoscopy Rooms
Dental operating room
Emergency room
measures space
Preparation room
Puli Space Awareness (Recovery)
Hemodialysis space
Vacuum is supplied via the central medical gas comprising:
1. Vacuum pump type Oil Rotary Vane.
Motor: 2.2 KW induction motors, 3 Phase, 200/220 Volt, 50Hz
Flow rate: 58 m³ / h
Rev the engine: 1420 rpm.
2. Receiver Tank
3. Vacuum Line Bacterial Filter
Used to remove bacteria and other contaminants on the entry side of the vacuum pump. Avoiding contamination of the pump and the surrounding air.

Medical gas type installed in central systems are:
a. oxygen
b. nitrous Oxide
c. Air Compressede
d. Vacuum (Suction)

4. MEDICAL GAS INSTALLATIONS
Part of the job of medical gases:
a. piping
b. Main valve or shut off valve (zone valve)
c. alarm system
d. Medical outlet

Pressure gas out of the outlet must meet the standards of medical press, namely:
a. Oxygen = 4 -5 kg ​​/ cm²
b. Nitrous Oxide = 4-5 kg ​​/ cm²
c. Compressed Air = 4-5 kg ​​/ cm²
d. Suction (Vacuum) = 20-60 cm Hg

Untuk keterangan lebih lanjut, silahkan download PDF ini :

Ulasan

/5
Ulasan
5
4
3
2
1

Foto dari Pembeli

Ulasan dari Pembeli

Filter
Semua
Dengan Foto
5
4
3
2
1
Telepon
Request a Quote
Produk Siap di Pesan
Rp 0
1

For more information please send me a message or contact us!

Search

Please enter the words you want to search in the field below

Bendera Indonesia Indonesia  |  Bendera Inggris English
Ingin menghubungi kami?
Klik tombol dibawah
Logo IDT
Chatbot